Booth electrical and power planning: complete guide
From load calculations to cable routing and LED specs — how to design an electrical system that doesn't deliver surprises on show day.
The short answer: a typical 20 m² booth needs 2-3 kW total power for lighting + screens + demo equipment. Most venues provide 16A (3.5 kW) outlets. Critical decisions: separate circuits for high-demand items, LED voltage planning, surge protection. Below is the complete electrical planning guide with real load calculations.
Why electrical planning matters
Booth electrical failures on show day = catastrophe:
- Demo equipment failure: lost lead opportunities
- Lighting goes out: booth looks unprofessional
- Tripped breakers mid-show: several minutes of dead booth
- Fire safety inspection failure: booth doesn’t open
Pre-planning electrical avoids 95% of these issues.
Power requirements per element
Lighting
LED spots (10-20W each): 8-12 fixtures for 20 m² booth = 80-240W total LED strips (15W/m): 6-10m around booth = 90-150W Backlit graphics (LED panels 40W/m²): 2-4m² = 80-160W Architectural LED features: 50-200W Total lighting: 400-750W for a 20 m² booth
Display equipment
55” LED TV/monitor: 100-150W 65” LED TV: 120-180W 75” TV/larger: 150-250W Video wall (modular): 200-500W Touch screen: 50-100W Demo computers: 50-150W each
Audio
Booth-fill speakers (60W each): 120-180W for typical setup Mini sound system: 100-200W Live audio (DJ booth, etc.): 500-1,500W
Demo and interactive equipment
Tablet stations: 20-30W each Charging stations: 100-200W total Coffee machine: 1,000-2,000W Mini fridge: 50-100W Demo machinery: varies (always check specs)
Lead capture equipment
Badge scanners: 5-10W each (USB powered) Printers: 50-300W Wi-Fi routers: 5-15W
Realistic power budgets
For a 20 m² booth, typical totals:
Light usage booth (basic):
- Lighting: 500W
- One screen: 150W
- Audio: 100W
- Charging: 100W
- Total: 850W (under 1 outlet)
Medium usage booth:
- Lighting: 700W
- Two screens: 300W
- Audio: 200W
- Demo equipment: 200W
- Charging: 100W
- Total: 1,500W (well within 16A outlet)
Heavy usage booth:
- Lighting: 1,000W
- Video wall: 500W
- Audio: 300W
- Demo machinery: 800W
- Coffee/catering: 1,500W
- Total: 4,100W (needs 2× 16A outlets or 32A)
Outlet types at venues
Standard outlets
16A single-phase (most common): 3.5 kW capacity
- Standard for 20-30 m² booths
- 1-2 outlets typically included in floor space
32A single-phase: 7 kW capacity
- Required for heavy demo equipment
- Extra cost €100-300
63A three-phase: 43 kW capacity
- Industrial booths only
- Significant extra cost
Connection types
CEE 16A “Blau” (Type CEE 7/4): standard EU industrial outlet, blue colour Schuko (Type F): standard household outlet (Germany, Austria, Greece) French Type E: France, Belgium UK Type G: United Kingdom USA Type B: US shows only
Circuit planning
Don’t put everything on one outlet. Distribute load:
Booth circuit organisation:
Circuit 1 (Lighting): all booth lighting Circuit 2 (Display): TVs, screens, video walls Circuit 3 (Demo): demo equipment, computers Circuit 4 (Catering/Misc): coffee, charging, ancillary
Benefits:
- One circuit fails, others continue
- Easier troubleshooting
- Compliance with venue rules
Load balancing
Avoid putting all high-demand items on one outlet. Distribute:
Bad: 2.5 kW on one 16A outlet = 90% capacity, risky Good: 1 kW + 1 kW + 0.5 kW spread across 2-3 outlets
Cable management
Cable types
Power cables: 3-core, 2.5 mm² standard. CE marked. LED ribbon cables: low-voltage (12V/24V) cables Data cables: Ethernet for demos requiring internet
Cable routing rules:
- Avoid walking paths
- Use floor protectors over crossing points
- Cable trays for multiple parallel runs
- Colour-code for identification
Cable hiding:
- Inside booth walls (preferred)
- Under raised flooring (premium)
- Cable management panels (visible but neat)
- Floor protectors (basic but functional)
LED specifics
LEDs are 95% of modern booth lighting. Plan carefully:
Voltage
12V LED strips: lower brightness, shorter runs (max 5m) 24V LED strips: higher brightness, longer runs (max 10-15m) 220V mains LED: standard fixtures, no voltage conversion
Drivers (power supplies)
Each LED installation needs a driver:
- Calculate total wattage
- Choose driver with 20% headroom
- Quality drivers cost €30-150 each
Voltage drop calculation
Long LED runs lose voltage. For 24V:
- Up to 5m: minimal drop
- 5-10m: 5-10% drop
- 10m+: requires multiple feed points
Sign of voltage drop: LED strips dimmer at end of run.
Safety considerations
RCD/RCBO protection
Residual current devices that trip on electrical fault. Mandatory in the EU.
RCD: single trip for whole booth RCBO: individual protection per circuit (preferred)
Surge protection
Important for demo equipment, screens. Cost €30-100. Worth installation.
Emergency shutoff
Visible kill switch for emergencies. Required at large booths.
Grounding
All metal structures grounded. Aluminium booth = full grounding needed.
Pre-show electrical checklist
2 weeks before show:
- Total power calculation done
- Outlet types confirmed with venue
- Extra outlets ordered if needed
- All equipment specs documented
- LED drivers selected
- Cable lengths planned
- Surge protection ordered
- Licensed electrician booked (if required by venue)
- Test connections planned
At-show electrical testing
Day -1 (during setup):
Test 1: all circuits power on Test 2: each fixture works Test 3: full load test (everything on at once) Test 4: check for overheating circuits Test 5: cable safety check
Day 0 (before opening):
- Final power-on test
- Walk-through with electrician
- Backup plans documented (e.g., switching to backup outlet)
Common electrical mistakes
Mistake 1: Forgetting demo computer wattage. Adds up quickly with 3-4 demo stations.
Mistake 2: Single circuit for everything. One blown = booth dark.
Mistake 3: Cable trip hazards. Visitors trip = liability issue.
Mistake 4: Wrong voltage equipment. US equipment in EU = transformer needed.
Mistake 5: No surge protection. One power spike = €1,000+ damage.
Mistake 6: Insufficient lighting circuit. Lights flicker, look cheap.
Mistake 7: No backup plan. When electricity fails, no contingency.
Frequently asked questions
Are venue electrical systems reliable? Generally yes at major venues. Smaller venues can be flaky. Plan for backup.
How much does electrical capacity affect demos? Significantly. Underpowered = demos run slow or crash. Plan for 30% headroom.
Is UPS battery backup necessary? Recommended for critical demos. Cost €200-1,000.
Is cable thickness important? Yes. Undersized cables overheat. Use 2.5 mm² minimum for 16A circuits.
How long do LED systems last in continuous operation? Quality LEDs: 25,000+ hours. Show usage (30-50 hours/show) = 500+ shows.
Is sharing outlet with neighbour ethical? Usually prohibited by venue rules. Causes overload issues.
How early should I order extra outlets? 4 weeks before show. Last-minute orders cost double.
Is circuit breaker info necessary for insurance? Yes — document electrical setup. Insurance claims require evidence.
How do I handle international electrical differences? Hire local electrician at the venue location. Adapt equipment or transformers.
Are floor power strips reliable? Yes if CE marked. Floor positioning critical to avoid trip hazards.
Designing a booth with complex electrical needs? Send us the details and we’ll design an electrical plan for your equipment. Also read permits & fire safety and exhibition booth lighting.